Area of Activities and Case Studies 

  • Solar Power Farm Projects (0.5 MW - 10.0 MW)

    At Langford Systems Ltd, we’ve been designing, installing and commissioning solar power plants projects for businesses to meet their green energy goals. Our expert team are here to guide you on your green journey and provide a bespoke solar package for your business that meets your energy requirements, both now and in the future. We offer an end-to-end process that can include:

    • Solar panel and battery options.

    • Preliminary proposal, site survey and final tailored solution.

    • Potential to sell excess energy generated back to grid.

    • Nationwide installation with health and safety at its core.

    • Management of the Distribution Network Operator (DNO) approval process.

  • Monocrystalline Solar Panels

    Langford Systems Ltd is the legal and official Agent Distributor of one of the best solar panels' manufacturer in China. The agreement gives our company the licence of providing the customers in UK, Middle East, North Africa and Africa with high quality solar modules for different projects. Solar panels certificates are; IEC 61215/IEC 61730, ISO9001, ISO 14001 and OHSAS 18001. The available solar panels types are;

    • Silver Solar Panels: 430 - 450W, 435 - 455W, 485 - 505W, 530 - 550W, 535 - 555W, 585 - 605W, 645 - 665W, 670 - 700W.

    • Full Black Solar Panels: 400 - 420W, 535 - 555W, 670 - 700W.

    • Bifacial Solar Panels: 530 - 550W, 585 - 605W, 675- 700W.

Design, Procurement, Construction, Erection, Testing, Commissioning and Training of Oil Storage Tanks

Design and Engineering Work

We, Langford Systems Ltd, are detailed, customised, design by our experienced team of engineers, using the latest 2D and 3D software, ensures the optimal tank solution is achieved, every time. Our team are capable of designing a range of storage tanks, stainless steel storage tanks and double walled storage tanks. From a single bespoke pressure vessel to a complex turn-key factory expansion, a detailed design is essential to ensure a smooth project delivery, on time and within budget. Langford Systems Ltd delivers the complete end-to-end solution for welded storage tank customers, from design to installation. We work to the following design codes; Cylindrical (BS EN 14015, BS EN 12285-2, BS EN 1993-4-2, API-620, API-650). Furthermore, Rectangular and Custom Shapes (BS799-5, Finite Element Analysis and In-House calculation spreadsheets).

Procurements Work

Our procurement team is the cornerstone of our successful storage oil tank projects, managing a complex, end-to-end supply chain to ensure seamless execution. We specialize in the strategic sourcing and acquisition of all critical components—from high-grade carbon steel plates and specialized welding consumables to advanced coating systems, heating coils, and safety instrumentation. Through rigorous vendor qualification, technical bid analysis, and stringent quality surveillance, we guarantee that every material and equipment piece not only meets project specifications but also adheres to the highest international standards (such as API 650, ASME, and ISO). By meticulously managing lead times, logistics, and cost control, we provide a reliable procurement service that de-risks the project timeline and upholds our commitment to integrity, safety, and operational excellence.

Civil and Foundation Works

Our civil and foundation works form the critical, load-bearing base for all our storage oil tank projects, ensuring long-term stability and integrity. The process begins with a comprehensive geotechnical investigation to analyze soil bearing capacity and settlement parameters. Our team then executes precise earthworks, followed by the construction of a robust foundation, typically a reinforced concrete ringwall designed to stringent API 650 standards. This includes meticulous soil compaction, the installation of leak detection systems, and corrosion-protected pipe sleeving. We manage all associated civil works, including paving, drainage, and bund wall construction, to create a complete and secure containment facility. Our rigorous quality control throughout this phase guarantees that the foundation will reliably support the tank's massive static and hydrostatic loads for decades

Fabrication, Erection Testing and Commissioning

The fabrication, erection, testing, and commissioning of our storage oil tanks is a meticulously sequenced operation executed with precision and unwavering attention to quality. It begins with the controlled fabrication of steel plates, including cutting, bevelling, and rolling to exacting tolerances. Our skilled teams then employ the jacking and hoisting method for the tank erection, carefully assembling the bottom, shell courses, and floating roof (if applicable) with strict adherence to weld procedure specifications. Following erection, we conduct rigorous testing, including radiographic and ultrasonic examination of critical welds, and a definitive hydrostatic test to verify the tank's structural integrity and leak-tightness. Finally, the commissioning process brings the tank to life, involving the calibration of instruments, testing of safety systems, and operational checks.

Get a Free, No Obligation Consultation

Are you ready to improve the energy efficiency of your business?
We would be delighted to guide you through your options.
Email us at info@langfordsystems.com, call us on +44 (0) 7776796615.

Discover More !
Contact Us:

124 City Road, London, EC1V 2NX, United Kingdom

+44 (0) 7776796615

info@langfordsystems.co.uk

9:00 am - 5:00 pm, Monday to Friday